Patrol clock tool

Uptime budget calculator

Type an uptime target and a period to see how much downtime that target allows, or type the downtime you had to see the uptime it leaves. Every result is an estimate from the plain arithmetic shown below, using only the numbers you enter.

Panel A

Downtime budget for a target

Period

How often your monitor checks. Used to show how many failed checks in a row the budget covers.

Enter a target, or pick one above, to see the downtime it allows.

Panel B

Uptime you achieved

Downtime you had
Over this period

Enter the downtime you had to see the uptime it leaves.

How it is worked out

allowed downtime = period × (1 − target ÷ 100)

achieved uptime % = (1 − downtime ÷ period) × 100

check intervals covered = allowed downtime ÷ check interval

whole failed checks = floor(check intervals covered)

  • Periods are fixed lengths: a day is 86,400 s, a week 604,800 s, a month is taken as 30 days (2,592,000 s) and a year as 365 days (31,536,000 s). For targets below 100 %, a 31-day month allows a little more downtime and February a little less. The month and year lengths are fixed assumptions made for this calculator. The conversions 1 min = 60 s, 1 h = 3,600 s and 1 day = 86,400 s are listed in the NIST Guide to the SI, Chapter 5, Table 6, published by the National Institute of Standards and Technology: Units outside the SI.
  • All downtime counts, planned or not, unless the target you are working to says maintenance is excluded.
  • The failed-check figure assumes your monitor logs each failed check as one full interval of downtime, from the first failed check to the next good one. Monitors that retry before marking a service down log it differently.
  • Results are rounded for display and are estimates. The calculator knows nothing about your monitor, your services or how they are measured.

For the idea of treating allowed downtime as a budget, see the chapter "Embracing Risk" in Site Reliability Engineering, published by O’Reilly Media and hosted online by Google.

Downtime allowed by common targets

Worked out with the formula above (estimates, rounded).

Allowed downtime for common uptime targets over each period
TargetDay 24 hoursWeek 7 daysMonth 30 daysYear 365 days
99 % 14 min 24 s1 h 40 min 48 s7 h 12 min3 d 15 h 36 min
99.5 % 7 min 12 s50 min 24 s3 h 36 min1 d 19 h 48 min
99.9 % 1 min 26 s10 min 5 s43 min 12 s8 h 45 min 36 s
99.95 % 43.2 s5 min 2 s21 min 36 s4 h 22 min 48 s
99.99 % 8.6 s1 min4 min 19 s52 min 34 s
99.999 % 0.86 s6 s25.9 s5 min 15 s